Automation Devices
|
|
|
 |
 |
|
| ³ÌÐò¿ØÖÆÆ÷ºÍ×Ô¶¯»¯É豸 |  |

Trendsetting Industrial Controls: SE-604, SE-606, SE-607 and SE-609

The controllers differ in the size of the high-contrast TFT color display (6,5 - 15 inch). For fast signal processing works a 600MHz fast Pentium based 32bit processor. A user friendly operation is achieved over the clearly arranged control dialogue and 34 operating keys / touch keys. The operating system VxWorks provides for the extremely high working reliability. In the control works a IEC61131 PLC(CoDeSys), which achieves the performance of a middle hardware PLC. The well-known advantages of CoDeSys, like fast setting, practical and user friendly handling and high performance, can be used. All data are stored on a Compact Flash Card (CF). Field bus communication is made over the STANGE remote CAN peripherals, optionally over Profibus. The connection to a process control system is made over the TCP/IP interface (100Mbit). The integrated Web server makes possible the operation by remote control via Internet Browser.
The requirements of modern furnaces engineering have influenced the development of the software applications considerably. Up to 30 control zones are processed by the control. The alarm processing stores up to 200 messages and represents these in the alarm history clearly (alarms can be sent away over SMS/E-Mail). The integrated recipe management permits the creation of maximally 250 recipes (programs). The programmer processes up to 30 set values and 64 control tracks.
8 login level increase the working reliability, over which the right of access of the users on the configuration and the operation are defined. For process visualization is available an operating set value curve. This permits the representation of 2 set and 3 actual values (configurable) with time bars and zoom function for the expired curve part.
The simple and safe operation of the processes as well as the integration of all process and automation technical requirements (nitriding potential control, online diffusion, recorder function) for modern heat treatment procedures are realized in the control with an excellent cost/performance ratio.
|
|
|
 |
|